Update the firmware of Hantek2D72/2D42/2C72/2C42
Edited by amy at 2019-11-25 09:53Update the firmware of Hantek2D72/2D42/2C72/2C42
Update with DFU software.
1. Download the programming tool in the following link and install. http://hantek.com/en/ProductDetail_1_13174.html
2. Press F1 and Power on button of the oscilloscope at the same time to enter programming mode.
3. Connect the oscilloscope to the computer and open the device manager of the computer.
4. Find a new device and right click it to update the driver. The driver files are in this path: STMicroelectronics\Software\DfuSe v3.0.5\Bin\Driver.
5. Open DfuSe Demo software, click "Choose" to select the firmware (***.dfu), and click "Upgrade" to update the firmware. After updated, click "Leave DFU mode" to exit the programming mode.
Also, users can use the software to update the firmware.
1. Download the software in the following link and install. http://hantek.com/en/ProductDetail_1_13174.html
2. Connect the scope to your computer via the USB cable.
3. Run the software Hantek2xx2.
Confirm the scope is connected to the computer successfully.
If not, please open the device manager to install the driver maunally.
4. Click "Help->CheckUpdate" to open HT2xxAutoUpdate software, now update according to Wizard.
Edited by AxGxP at 2019-12-13 08:22
Баг с выключением при переходе с 50ms на 20ms исправлен!
Баг с автоматическим переключением из режима Roll в режим Y-T испрпавлен!
Порошивка одинаковая на всех этих осциллографах. 2C42/2D42/2C72/2D72
Edited by AxGxP at 2019-12-12 12:49
Ну что... Разработчики игнорят, пришлось самому всё делать.
Ловите и наслаждайтесь!
Мною проведены исправления!
Прошивка создана на основе HantekHTX2019110801.
Что изменено:
Уменьшено время отображения меню с 17 секунд до 8 секунд.
Исправленны назначения кнопок, в режиме настройки усилителя и развёртки.
Теперь стрелка вправо увеличивает амплитуду отображаемого сигнала, а стрелка влево уменьшает.
Стрелка вниз замедляет развёртку, стрелка вверх ускоряет.
Теперь управление как на любом нормальном осциллографе!
И наверное самое главное:
Теперь можно переключаться между настройками не вызывая отображения меню!
Нажатие кнопок F1,F2,F3,F4 не вызывает появление меню.
F1 активирует настройку усилителя Ch1.
F2 активирует настройку усилителя Ch2.
F3 активирует настройку Trig.
F4 развёртки Time.
Все остальные функции работают как в оригинальной прошивке. Но появился сложно преодолимый баг:
Режима ROLL теперь не переключается автоматически в режим Y-T, при ускорении развертки выше 100мс/дел.
There are no updates for 2 months. If you do not want to update, then give people the source code.
alik3t replied at 2019-12-13 18:31
AxGxP здравствуйте.
Извините что пишу ещё раз. В коммента ...
Теоретически всё возможно... Но практически - очень сложно осуществимо...
У меня нет исходников программы, есть только возможность редактировать заводскую прошивку, ограничиваясь её адресацией... Там много всякого лишнего, что-то можно выкинуть, немного переделать, изменить, но только в рамках существующего кода и в рамках его размера.
Я не могу просто взять и добавить какой-то функционал, которого там нет вообще, не убрав чего-то другого.
Вполне вероятно, что проще написать полностью свою прошивку, чем исправить все недостатки и доделать эту.
Если будет время я ещё покопаю... Есть желание добавить возможность изменять частоту генератора, не выходя из режима осциллографа.
Для кардинальных изменений и улучшений нужно иметь исходники...
Edited by borsuk at 2020-7-22 06:00
amy replied at 2020-7-10 08:37
Sorry, I can't understand what is meant by battery operation. Please discribe again.
So, Dear, someone will help me with this problem, it does not matter, but it is better to have an indication that the device is turned on. Thank you for any help.
AxGxP хочу сказать вам огромное спасибо, за проделанную работу. Вы воплотили большинство исправлений, которые просили люди у разработчика на протяжении целого года. Единственное, что осталось изменить без серьезного редактирования кода, это изменить цвет фонаmenu measurement, с серого на черный. Ну или хотя бы на темно серый. Ибо реально порой трудно рассмотреть показания, даже имея хорошее зрение.
Edited by OASJ2YSeeEhBQo1 at 2019-12-12 23:29
AxGxP replied at 2019-12-12 08:31
Ну что... Разработчики игнорят, пришлось самому всё дел ...
Nice job! I will be testing the mods and I'll report back.
It's a shame that hantek doesn't care to improve the software of its devices. If they open sourced the code we would have by now a useful device and they would be selling 10x more of it.
what about make menu hide on pressing "Enter" or "Menu" second time?
Change button Left<->Right in Channel Mode (voltage/division)?
Change button Up<->Down in Time Mode (seconds/division)?
Is it so hard to make this changes?
Please! Do it!
Joy-It has now provided a firmware that can be updated directly via DfuSe Demo. I have tested it with my Hantek 2D72 and the flashing process did work flawlessly.
If the manufacturer does not want to upgrade the device and fix bugs in the software, can you get the firmware in its original form? I think then the craftsmen would write a normal firmware. Which would fix and add a lot. I think there is no secret in the firmware so that the manufacturer does not give the source code.
Can we get software to change it and upgrade?
Edited by amy at 2019-11-25 09:44
Firmware version: 2018110201
Firmware version: 2018111501
Firmware version: 2018120601
Firmware version: 2019010401
Firmware version: 2019022001
Firmware version: 20190030201
Firmware version: 2019041501
Firmware version: 2019060601
Firmware version: 2019082401 Void
Firmware version: 2019082801
Firmware version: 2019110801
Hi Amy, I have a question about the firmware. Instead of showing amplitude, can it instead show minimum and maximum? Right now the firmware shows "amplitude = maxiumum - minimum" which is less usefull than just maximum and minimum. Please ask the firmware/software team to look at this.
Hi. From the official page http://hantek.com/ProductDetail_5_9242.html. Not working download links:
http://hantek.com/down.aspx?url=http%3a%2f%2fwww.hantek.com%2fProduct%2fHantek2000%2fHantek2000_Firmware.zip
http://hantek.com/down.aspx?url=http%3a%2f%2fwww.hantek.com%2fProduct%2fHantek2000%2fHantek2000_FPGA.zip
dmitrius replied at 2018-12-1 02:29
Hi. From the official page http://hantek.com/ProductDetail_5_9242.html. Not working download links:
...
Sir, we have updated the link, please download again.
Where can I find the change log for these upgrades?
Sorry, we don't provide the change log.
OK, but the new firmware does provide new functionality? in order to upgrade it, is it necessary upgrade the fpga code first?
Thanks
Ich würde gerne mein Hantek 2c42 auf den neusten Stand bringen.
Was muss ich machen.
was ist der Fpga-Code und muss er auch aktualisiert werden ??
(I would like to update my Hantek 2c42.
What should I do.
what is the Fpga code and does it have to be updated ??)
dpcdietmar replied at 2018-12-16 22:41
Ich würde gerne mein Hantek 2c42 auf den neusten Stand bringen.
Was muss ich machen.
was ist der Fp ...
Sir, please press Menu->sys info to check the FPGA version.