Step 2: Press on the front panel to open a menu that specifies whether the DMM will beep to indicate a successful diode test.

Diode measurements behave as follows:


WisdomAugust Publish time 2023-7-24 08:24:16

Frequency and Period This section describes how to configure frequency and period measurements from the front panel. Step 1: Configure the test leads as shown.


Eastojamson Publish time 2023-7-25 14:58:08

You actually make it look so easy with your performance but I find this matter to be actually something which I think I would never comprehend. It seems too complicated and extremely broad for me. I'm looking forward for your next post, I’ll try to get the hang of it!        Tea Packing Machine

Eastojamson Publish time 2023-7-30 16:39:43

I have express a few of the articles on your website now, and I really like your style of blogging. I added it to my favorite’s blog site list and will be checking back soon…        continuous ketone monitor

WisdomAugust Publish time 2023-8-1 08:34:25

Step 2: Press on the front panel and then use the first softkey to choose either frequency or period measurement.

Step 3: Press Range to select a range for the measurement. (Auto (autorange) automatically selects the range for the measurement based on the input. Autoranging is convenient, but it results in slower measurements than using a manual range. Autoranging goes up a range at 120% of the present range, and down a range below 10% of the present range.


WisdomAugust Publish time 2023-8-2 08:23:50

Step 4: Press AC Filter and choose the filter for the measurement. The instrument uses three different AC filters that enable you either to optimize low frequency accuracy or to achieve faster AC settling times following a change in input signal amplitude. The three filters are 3 Hz, 20 Hz, and 200 Hz, and you should generally select the highest frequency filter whose frequency is less than that of the signal you are measuring, because higher frequency filters result in faster measurements. For example, when measuring a signal between 20 and 200 Hz, use the 20 Hz filter. If measurement speed is not an issue, choosing a lower frequency filter may result in quieter measurements, depending on the signal that you are measuring.


WisdomAugust Publish time 2023-8-3 08:54:41

Step 5: Press Gate Time and choose the measurement aperture (integration time) of10 ms, 100 ms (default), or 1 s.

Step 6: Press Timeout to control how long the instrument waits before timing out on a frequency or period measurement when no signal is present. When set to 1s, the instrument waits 1 second before timing out. When set to Auto, the wait time varies with AC filter bandwidth; for the faster bandwidths, the instrument waits a shorter time before timing out and returning 0.0. This is advantageous in manufacturing test systems where a DUT failure may result in no signal; in this case, the failure can be detected sooner, speeding up test throughput.

NOTE For accurate displayed statistics of AC measurements in Front Panel mode, the default manual trigger delay ( > Delay Man) must be used.

WisdomAugust Publish time 2023-8-4 08:09:21

Secondary Measurements Most measurement functions allow you to select and display a secondary measurement function. Secondary measurements can be displayed in the Number and Bar Meter displays only. For example, a thermistor temperature measurement (primary) and the resistance measurement made on the thermistor (secondary) are shown below:


WisdomAugust Publish time 2023-8-7 08:09:25

To select a secondary measurement from the front panel, first select the primary measurement function and then press Display:

Press 2nd Meas and select the secondary measurement. The primary measurement functions and their associated secondary measurements for each DMM model are:


WisdomAugust Publish time 2023-8-8 08:15:45

Where: l Sensor - The raw sensor value; ohms for thermistor/RTD. l Input/Ref - The DC signal voltage and the DC reference voltage measurements. 1 After making one or more primary measurements for approximately 4 seconds, the DMM makes one secondary measurement.

Triggering and Readings The trigger model and large reading memory provide versatile capabilities for a wide variety of applications.